W.O. 040Before you call

What to check, and what to shut off.

Most of what follows you can check in five minutes, and some of it will fix the problem outright. The rest tells you what to shut off before it gets worse. None of it needs a technician standing there.

None of this needs a technician standing there. Some of it will fix the problem outright.

No heat

Before you call, run these.

  • Thermostat set to Heat, and the target above current room temperature
  • Furnace switch near the unit is on, and the breaker has not tripped
  • Filter is not clogged. Replace it if you have a spare
  • Oil furnace: check the tank gauge is not sitting on empty
  • If the burner locks out repeatedly, note the error light pattern before you reset it

That error light pattern saves real diagnosis time. Write it down or photograph it.

Frozen pipes

Nothing coming out of the tap.

  • Open the nearest faucet slightly to give the thaw somewhere to go
  • Shut the water off at the main if you see a bulging pipe or an active split
  • Never use an open flame to thaw a line
  • Photograph any split before you shut everything down

Thawing an accessible line starts around $169, plus repair if the pipe split.

Heat pump icing

Ice on the outdoor unit.

  • Light frost in cold humid weather can be normal
  • A defrost whoosh once or twice an hour is normal
  • Shut it down if the coil is a solid block of ice
  • Shut it down if indoor airflow has gone weak, or you hear grinding
  • Clear leaves and drifted snow from around the unit if you can reach it safely

Open a ticket with a photo if you can. Blocked airflow, a failed defrost board, and drainage all look similar in words and different in a picture.

Carbon monoxide

This one is not a checklist.

  • Alarm sounding its danger pattern, or anyone dizzy or headachy: leave the house
  • Call 911 first. Not us
  • Shut the appliance off only if it is safe to do so on your way out
  • Open a ticket once everyone is out and clear

We inspect heat exchangers, venting, and draft during fall service. We do not disable CO alarms to silence them.

W.O. 041Before the first freeze

The October list.

The cheapest call is the one that happens now instead of in January. Inspection slots fill fast after the first cold forecast.

  • Book furnace or heat pump service before the first sustained freeze
  • Clear leaves and snow drift paths from around the outdoor heat pump
  • Know where your water main shutoff is before you need it
  • Drain or shut off hose bibs for the winter, and leave the taps open
  • 1-inch filters every 1 to 3 months. Thicker media filters, follow the label, usually 6 to 12 months

Checked all that and still cold?

Tell us what you already tried. It saves the tech twenty minutes and saves you the cost of them.